View Full Version : How to add 82/91 dish to existing motor setup
ADABman
05-19-2014, 09:42 PM
Hi,
I currently have a Dreamlink T5 going to SG6100 motor, then to 4x1 Diseq switch. Ports 1 and 2 from switch go to Invacom QPH-031 quad. All is working well here.
I would like to add an existing unused Telus dish into the mix for faster access to 82 and 91. It had a single coax from it to a receiver. It looks like this:
21780
How could I add this to the mix? Run it to port 3 of the diseq 4x1 switch? IF so what settings to use for that LNB :noidea:
Thx
Benney
05-19-2014, 11:08 PM
That's a dish pro plus and I am sure you can't mix it with the Inviacom that is a legacy. Actually I'm positive you can't.
Get two DishPro legacys and run a wire from each LNB to ports 3 and 4 of your switch.
Terryl
05-19-2014, 11:20 PM
I actually had my Invacom motorized setup working with a D500 twin LNB, and it worked quite well.
How to do this is you run the #3 and #4 ports on your switch to the Invacom "C" and "L" outputs, then the #1 port of the switch goes to the first LNB output on the DP twin LNB, the #2 port on the switch goes to the second port on the DP twin.
Switching is Diseqc #1= 91 (I think) Diseqc #2 = 82, Diseqc #3 = Invacom Circular port, Diseqc #4 = Invacom Linear port, then the output of your switch goes through the motor then to your receiver.
My setup worked quite well until they put up the new birds for 91 and 82, I also had to run better coax to the motor and the DP twin LNB.
And as far as the settings, you would have to use OCS-DP or Dish, as your LNB type.
This way the Diseqc commands are still in the right format for the DP twin LNB.
Benney
05-19-2014, 11:22 PM
Cool I never thought of doing it that way.
Thanks.
Terryl
05-19-2014, 11:35 PM
Yah I had to play with it a bit, found out that the DP twin will work fine if you don't change the Diseqc switching order, it must be in the #1 and #2 Diseqc switch priority, it also works fine for 110 and 119, you just have to put the Invacom on the #3 and 4 ports.
NOTE: this will NOT work with a DP Plus twin LNB, it it has the second external LNB input on it, it will not work as that type of LNB is looking for a third DP LNB on that port, and the Diseqc switch #3 will mess up, and the whole thing will crash.
It must be a DP twin, and not a DP plus twin, how to ID the DP plus LNB is by looking at the number of "F" connectors on the LNB, if it has 3 then it wont work, 2 or 4 will work fine.
Powered by vBulletin® Version 4.2.5 Copyright © 2025 vBulletin Solutions Inc. All rights reserved.